Audit Services — pqExcel Solutions LLP

Home  /  Products & Solutions  /  Audit Services

Audit & Engineering Study Services

Measurement-driven audits and engineering studies — identifying risks, inefficiencies, and compliance gaps before they become problems.

Our approach

Understand first. Act on evidence.

Every effective engineering solution begins with accurate measurement and honest assessment. pqExcel's audit and engineering study services are designed to give you a clear, data-backed picture of your electrical system's performance — identifying what needs attention, why, and what to do about it.

Our audits are conducted by experienced engineers using calibrated instruments — delivering structured reports with findings, analysis, and actionable recommendations. Whether you need to verify compliance, identify power quality issues, assess electrical safety risks, or establish an energy baseline, we bring the right methodology and the right tools to every engagement.

Audit before solution — pqExcel recommends an audit or measurement study before any mitigation or system solution is proposed. This ensures every recommendation is grounded in actual site data — not assumptions.

🔍

Power Quality Audit

Harmonics, voltage quality, power factor — IEEE 519 & EN50160 compliance

⏩

Harmonic & Reactive Power Study

Detailed harmonic analysis and reactive power assessment

🌡

Thermography Audit

Infrared thermal scanning for hotspot detection and risk assessment

⚡

Relay Co-ordination Study

Protection device settings for selective, reliable fault clearance

💧

Arc Flash Study

Incident energy analysis and electrical safety assessment

What we offer

Our audit & study services

Five structured services — each delivering a clear, actionable report to support engineering decisions, compliance requirements, and safety improvements.

🔍

Power Quality Audit

A comprehensive assessment of your electrical system's power quality — measuring harmonics, voltage quality, power factor, and disturbance events to identify issues and verify compliance with IEEE 519 and EN50160 standards.

Deliverables
✓Site measurement using power quality analysers
✓Harmonic spectrum and voltage quality analysis
✓Load profile and power factor assessment
✓IEEE 519 and EN50160 compliance report
✓Recommendations for mitigation
⏩

Harmonic & Reactive Power Study

A detailed engineering study focusing on harmonic generation sources, distortion levels, and reactive power demand — providing the data foundation for correct sizing and selection of AHF, SVG, APFC, or hybrid mitigation systems.

Deliverables
✓Harmonic source identification and quantification
✓THD and TDD measurement and analysis
✓Reactive power demand profile
✓Solution sizing and selection recommendation
✓Engineering report with mitigation options
🌡

Thermography Audit

Infrared thermal scanning of electrical panels, switchgear, transformers, bus bars, and connections — detecting hotspots, loose connections, and overloaded components before they cause failures, fires, or unplanned downtime.

Deliverables
✓Thermal imaging of panels, switchgear, and connections
✓Hotspot identification with temperature readings
✓Risk classification — critical, moderate, low
✓Photographic evidence with thermal images
✓Corrective action recommendations
⚡

Relay Co-ordination Study

A systematic review and optimisation of protection relay settings across your electrical distribution system — ensuring selective, time-graded fault clearance that minimises disruption, protects equipment, and maintains system stability during fault conditions.

Deliverables
✓Single line diagram review and data collection
✓Short circuit and fault level calculations
✓Protection co-ordination analysis
✓Recommended relay settings for each device
✓Time-current characteristic curves and report
💧

Arc Flash Study

An incident energy analysis of your electrical distribution system — determining arc flash hazard levels at each equipment location, establishing safe working boundaries, and supporting selection of appropriate Personal Protective Equipment (PPE) for electrical workers.

Deliverables
✓System data collection and single line review
✓Incident energy calculations per equipment location
✓Arc flash hazard classification and boundary determination
✓PPE category recommendations
✓Arc flash labels and engineering report
Our philosophy

Measure before you act — every time

At pqExcel, every solution recommendation is preceded by measurement. Audits and engineering studies are not add-ons — they are the foundation of every engagement.

This approach ensures that solutions are sized correctly, investments are justified by data, and outcomes can be validated through post-implementation measurement.

📈

Accurate diagnosis

Site measurement reveals the true state of your electrical system — not what is assumed based on equipment specifications or historical incidents

🔍

Right solution, right size

Measured data ensures mitigation systems are correctly sized and specified — avoiding over-engineering or under-performance

🏅

Compliance documentation

Structured audit reports provide documented evidence for regulatory compliance, utility requirements, and internal audit purposes

✅

Validated outcomes

Post-implementation measurement confirms that solutions have achieved their design targets — giving you confidence in the investment

Ready to assess your electrical system?

Talk to our engineers — we'll recommend the right audit or study for your facility's requirements.

Schedule an audit View all solutions